TA-5000 Temperature Conditioners (from -85°C to +225°C)

Conditioner (Giraffe, Thermalstream) TA-5000 (from -85°C to +225°C)

The MPI ThermalAir TA-5000 High Capacity Temperature Conditioner System is used for temperature testing, rapid thermal cycling and temperature characterization of components, hybrids, modules, printed circuit boards and other electronic and non-electronic components at precise temperatures from -80°C to +225°C.

The TA-5000's DC-controlled power adjusts almost instantly to your temperature settings and real-time test conditions, providing precise temperature control when you need it while saving energy.

Some applications :

  • Failure analysis test
  • Hot/Cold Temperature Cycle Tests​
  • MIL-SPEC-883 Test Methods (Military and Space Applications)
  • Product Engineering
  • Semiconductor Back-End Testing
  • IC Test Handler ​
  • Functional test​
  • Cooling test
  • Environmental Stress Test

The TA-5000's strengths :​

  • Ergonomic and easily transportable device
  • Ultra-quiet !​
  • Eco-friendly with up to 50% energy savings.
  • The efficiency of ultra-stable direct current temperature control
  • Ultra-cold temperatures maintained at 50 and 60 Hz​
  • Two color touch screens on the station and head used for maximum ergonomics.
  • SSD for thermal file management and data logging
  • A single system worldwide compatible with all types of voltage and frequency​
  • No N2 or CO2 required (built-in air cooler and dryer).
  • Possibility of working remotely​

The equipment is available in two configurations : ​

  • Either with an articulated arm, allowing a double-walled glass bell or a hood to be fixed there, and bringing this test zone up to 140 cm of lateral offset in relation to the central axis of the equipment.
  • Either with a flexible hose between 60 and 180 cm long, on a 360° reel, allowing connection to a closed clamshell enclosure, or to your own chamber (anechoic, for example).

The TA-5000's integrated air drying and filtering system sends clean, dry air (CDA) through its powerful internal cooler/heat exchanger to provide setpoint temperatures.

The user can control the TA-5000's outlet temperature flow rate from 4 to 25 SCFM, with continuous flow over the entire temperature range, 24/7.

​The primary temperature control of the TA-5000 is achieved by the temperature thermocouple integrated into the outlet nozzle tip. ​ External thermocouples (type K or T) can also be used.

The MPI ThermalAir system also features multi-channel RTD and diode (resistance temperature detector) inputs for precise temperature control of the heat flow system.


Connect with our expert
Marie-Helene Bedelem
mh.beddelem@microtest-semi.com


Merci d'entrer vos coordonnées pour télécharger la fiche technique.